Cytation 1 Cell Imaging Multi-Mode Reader

Cell Imaging & Microscopy > Cell Imaging Multi-Mode Readers

Cytation 1 Cell Imaging Multi-Mode Reader

Overview:

Cytation™ 1 Cell Imaging Multi-Mode Reader combines fluorescence and high contrast brightfield imaging with conventional multi-mode detection without the expense and complexity commonly associated with other digital microscopy systems. This unique, patented design provides both quantitative phenotypic cellular information with well-based quantitative data. Cytation 1's multi-mode detection module includes high sensitivity filter-based fluorescence and a monochromator system for UV-Vis absorbance. Temperature control and shaking are standard; CO2/O2 control and reagent injectors are available. BioTek’s powerful Gen5 software makes image capture and plate reading easy.

   

Testimonials

Sachin
 

Seahorse XF Imaging and Normalization System

Cytation 1 is a key component of Agilent Technologies’ Seahorse XF Imaging and Normalization System. XFe Analyzers simultaneously measure the two major cellular energy-producing pathways, mitochondrial respiration and glycolysis, in live cells and in real time. The integrated solution with Cytation 1 combines cellular analysis and imaging for an intuitive workflow to streamline XF data interpretation.

Features:

 

   Digital microscopy and multi-mode detection

 
 
 High quality, high performance at an affordable price

Collect both phenotypic data and quantitative data from one instrument. Image and data analysis are provided with Gen5 software for all applications.

 

   Easy imaging workflow automation

 
 

BioTek’s Augmented Microscopy automates image capture, processing and analysis for publication-ready images and data. Automated image capture starts with image-based and laser autofocus, plus auto LED and exposure. Automated image pre-processing optimizes images for downstream analysis, from cell counting to characterization of subcellular details.

Four imaging modes, multiple imaging processes
 

   Fluorescence and high contrast brightfield imaging
 

 
 
 Label-free cell counting

The powerful imaging module in Cytation 1 offers four color channels plus brightfield, from 1.25x to 60x to capture large regions of interest or intracellular details. More than 15 filter/LED cubes are available, supporting a broad range of imaging applications.

 

  Affordable automation

 
 

Cytation 1 has an automated XY stage, autofocus, auto exposure and auto LED intensity for efficient capture of high quality images. The automated features in Cytation 1 and Gen5 make it easy for you to find the region of interest, then quickly find the best settings to capture the images. Gen5 software is simple to use, without extensive training.

Automated digital microscopy to 100x

More than 20 filter/LED color cubes

 
 
Four imaging modes, multiple imaging processes

BioTek has the most comprehensive selection of imaging filter and LED cubes available for use with our Lionheart and Cytation imagers. This large selection of colors enables image capture for a broad range of applications. Download our convenient Imaging Cube Selection Guide here.

 

  Cell friendly design

 
 

Live cell assays require an optimal environment. Cytation 1 has temperature control and shaking, plus CO2 / O2 control, to facilitate longer-term kinetic studies.

Automated digital microscopy to 100x

   High performance and convenience

 
 
Four imaging modes, multiple imaging processes

To optimize multi-mode detection, Cytation 1 has high performance filters for fluorescence and monochromator-based UV-Vis absorbance for convenient wavelength selection in 1 nm increments.

 

  Peltier Cooling for environmental stability

 
 

The Peltier Cooling Module promotes a rapid interior cool down after incubated processes, to allow efficient switching between multiple applications without unwanted temperature influences. For temperature sensitive assays typically run at ambient, or room temperature, the Cooling Module maintains environmental stability within Cytation, allowing < 1 °C rise in ambient temperature, regardless of external and internal temperature fluctuation.

Automated digital microscopy to 100x

Models:

 
CYT1FAV
CYT1FA
CYT1V
Fluorescence and high contrast brightfield imaging
 
Monochromator absorbance
 
Filter/dichroic fluorescence
 
Luminescence / filtered luminescence
 

Specifications:

General
Detection modes UV-Vis absorbance
Fluorescence intensity
Luminescence
Fluorescence polarization
Time-resolved fluorescence
Read methods Endpoint, kinetic, spectral scanning, well area scanning
Microplate types Monochromator: 6- to 384-well plates
Filters: 6- to 1536-well plates
Imaging: 6- to 1536-well plates
Other labware supported Microscope slides, Petri and cell culture dishes, cell culture flasks (T25), counting chambers (hemocytometer)
Take3 Micro-Volume Plates
Temperature control 4-Zone incubation to 45 °C with Condensation Control™; Variation +0.2 °C at 37 °C
Cooling Optional Peltier Cooling Module maintains internal temperature with < 1 °C rise over ambient. Provides internal cooling after incubated processes.
Shaking Linear, orbital, double orbital
Software Gen5™ Microplate Reader and Imager Software
Gen5 Image+ and Image Prime software available for full image analysis
Gen5 Secure available for 21 CFR Part 11
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible
CO2 and O2 control (option) 0 - 20% CO2 control and 1 – 19% O2 control, with optional Gas Controller
Models for both CO2 and O2 or CO2 only are available
Imaging - Inverted Microscope
Imaging mode Fluorescence and high contrast brightfield (2.5x Zeiss, 4x, 10x, 20x, 40x and 60x)
Imaging method Single color, multi-color, montage, time lapse, z-stacking
Image processing Z-projection, image stitching
Camera 16-bit gray scale, Sony
Objective capacity 2 user-replaceable objectives
Objectives available 1.25x, 2.5x (2.25x eff),2.5x (2.75x eff), 4x,10x, 20x, 40x, 60x
Image filter cube capacity 4 user-replaceable fluorescence cubes plus brightfield channel
Imaging filter cubes available DAPI, CFP, GFP, YFP, RFP, Texas Red, CY5, CY7,Acridine Orange (ACR OR), CFP-YFP FRET, propidium,Iodide, chlorophyll, phycoerythrin, CY5.5, TagBFP, Alexa568, Ex377 / Em647
Imaging LED cubes available 365 nm, 390 nm, 465 nm, 505 nm, 523 nm, 590 nm, 623 nm, 655 nm, 740 nm
Automated functions Autofocus, auto LED intensity, auto exposure
Autofocus method Image-based autofocus
User-trained autofocus
Laser autofocus (option)
Positional controls Software control
Image collection rate Image-based autofocus:
96 wells, 1 color (DAPI), 4x, 6 minutes
96 wells, 3 colors, 4x, 12 minutes

Laser autofocus:
96 wells, 1 color (DAPI), 4x, <3 minutes
96 wells, 3 colors, 4x, <7 minutes, 30 seconds Burst Mode: 10 fps, single well, single color at <= 50ms integration time
Image Analysis Software option Gen5 Image+: Image analysis
Gen5 Image Prime: Advanced image analysis
Gen5 Secure: 21 CFR Part 11 compliant features
Fluorescence Intensity
Light source Xenon flash
Detector PMT
Wavelength selection Deep blocking band pass filters / dichroic mirrors
Wavelength range Filters: 200 - 700 nm (850 nm option)
Dynamic range 7 decades
Sensitivity Fluorescein: 0.25 pM (0.025 fmol/well, 384-well plate)
Reading speed (kinetic) 96 wells: 11 seconds
384 wells: 22 seconds
Luminescence
Wavelength range 300 - 700 nm
Dynamic range >6 decades
Sensitivity 10 amol ATP (flash)
100 amol (glow)
Fluorescence Polarization
Light source Xenon flash
Detector PMT
Wavelength selection Filters
Wavelength range 400 nm – 700 nm
Sensitivity 1.2 mP standard deviation at 1 nM fluorescein
Time-Resolved Fluorescence
Light source Xenon flash
Detector PMT
Wavelength selection Filters
Sensitivity Europium 40 fM (4 amol/well, 384-well plate)
Absorbance
Light source Xenon flash
Detector photodiode
Wavelength selection Monochromator
Wavelength range 200 – 999 nm, 1 nm increment
Monochromator bandwidth 2.4 nm
Dynamic range 0 – 4.0 OD
Resolution 0.0001 OD
Pathlength correction yes
Monochromator wavelength accuracy + 2 nm
Monochromator wavelength repeatability + 0.2 nm
OD accuracy <1% at 2.0 OD
<3% at 3.0 OD
OD linearity <1% from 0 to 3.0 OD
OD repeatability <0.5% at 2.0 OD
Stray light 0.03% at 230 nm
Reading speed (kinetic) 96 wells: 11 seconds
384 wells: 22 seconds
Reagent Injectors (option)
Supported detection modes All modes
Number 2 syringe pumps
Supported labware 6- to 384-well plates, Petri and cell culture dishes
Dead volume 1.1 mL with back flush
Dispense volume 5 - 1000 µL in 1 µL increments
Plate geometry 6- to 384-well microplates
Dispense accuracy +1 µL or 2%
Dispense precision <2% at 50 – 200 µL
Physical Characteristics
Power 100-240 VAC, 50/60 Hz (24VDC external power supply, 150W min)
Dimensions 20.2" D x 16.4" W x 17.5" H
(51.4 cm D x 41.6 cm W x 44.5 cm H)
Weight 65 lbs (29 Kg)
Regulatory
Regulatory CE and TUV marked. Models for In Vitro Diagnostic use are available.