Cytation 5 Cell Imaging Multi-Mode Reader

Cell Imaging & Microscopy > Cell Imaging Multi-Mode Readers

Cytation 5 Cell Imaging Multi-Mode Reader

Overview:

 

Cytation™ 5 combines automated digital microscopy and conventional microplate detection in a configurable, upgradable platform. The microscopy module offers up to 60x magnification in fluorescence, brightfield, high contrast brightfield, color brightfield and phase contrast for maximum applications reach.  The multi-mode detection modules include filter- and monochromator-based fluorescence  detection, luminescence and UV-Vis absorbance detection. Gen5™ software provides complete control over all imaging and data capture, plus powerful image and data analysis.
 

Testimonials

Sachin
Joe
 

Seahorse XF Imaging and Normalization System

Cytation 5 is a key component of Agilent Technologies’ Seahorse XF Imaging and Normalization System. XFe Analyzers simultaneously measure the two major cellular energy-producing pathways, mitochondrial respiration and glycolysis, in live cells and in real time. The integrated solution with Cytation 5 combines cellular analysis and imaging for an intuitive workflow to streamline XF data interpretation.


Features:

 

   Digital microscopy and multi-mode detection

 
 
 Digital microscopy and multi-mode detection

Cytation 5’s patented design enables automated digital microscopy to be combined with conventional multi-mode detection to suit a broad range of imaging and biochemical workflows. Along with Gen5 software, Cytation’s imaging module comprises Augmented Microscopy – the ability to capture>process>analyze>publish high-quality data and images, to obtain both qualitative and quantitative information on live and fixed cell imaging applications.

 

Environmental controls facilitate live cell assays

 
 

Cytation 5 is well suited for live cell assays, with temperature control to 65 °C, plus linear and orbital shaking. A gas controller module is available to help regulate CO2 and O2 levels in the system for longer-term live cell requirements. A dual reagent injector provides quick inject/image capability for observing fast reactions.

Hella video
 

   Wide field of view camera for fast whole well imaging

 
 
    Wide field of view camera for fast whole well imaging

Capture an image of an entire well with the wide FOV camera - the image at left shows an image captured in a single well of 384-well plate at 4x. Further benefits of the wide FOV camera are fast capture speeds for large samples and statistically significant sampling for cellular population analysis.

 

   Label-free cell counting for cell proliferation studies

 
 

It’s fast and simple to count live cells using the available high contrast brightfield option. Higher contrast allows a direct and label-free method for object identification using Gen5 software to count cells and characterize cell proliferation in kinetic studies.

 Label-free cell counting for cell proliferation studies

   More than 20 imaging filter/LED cube colors reach many applications

 
 
colors

BioTek has the most comprehensive selection of imaging filter and LED cubes available for use with our Lionheart and Cytation imagers. This large selection of colors enables image capture for a broad range of applications. Download our convenient Imaging Cube Selection Guide here.

 

Patented Hybrid optics for fluorescence detection

 
 

Cytation 5’s hybrid optical design offers filter-based fluorescence optics for high transmission and high sensitivity, while the available monochromator optics offers convenience and assay flexibility. Multiple fluorescence measurement modes include fluorescence intensity, time-resolved fluorescence and fluorescence polarization.

hybrid optics
 

   Variable bandwidth monochromators

 
 
  Variable bandwidth monochromators

The bandwidths of the monochromators in Cytation 5’s fluorescence detection module are selectable from 9 nm to 50 nm, in 1 nm increments. Variable bandwidths allow you to optimize detection conditions for fluorophores that have unique excitation or emission parameters, for example, a narrow Stokes shift, to provide better performance than conventional monochromators.

 

   100 mW Alpha Laser

 
 

Laser-based excitation offers the power required to get great sensitivity and fast reading speeds, which are critical for Alpha assays.

Automated digital microscopy to 100x

   Modular, upgradable design

 
 
Four imaging modes, multiple imaging processes

Cytation 5 is a modular system, with imaging optics and multi-mode optics available in a variety of configurations and upgrade paths. The separate modules ensure excellent performance in imaging and all detection modes, without compromise Choose imaging only, with available phase contrast. Or, add filter- and/or- monochromator-based fluorescence and luminescence, UV-Vis absorbance along with available laser-based Alpha detection.

   Peltier Cooling for environmental stability

 
 

The Peltier Cooling Module promotes a rapid interior cool down after incubated processes, to allow efficient switching between multiple applications without unwanted temperature influences. For temperature sensitive assays typically run at ambient, or room temperature, the Cooling Module maintains environmental stability within Cytation, allowing < 1 °C rise in ambient temperature, regardless of external and internal temperature fluctuation.

Label-free cell counting

Models:

Imaging Plus Multi-Mode Configurations

Part #
CYT5FV
CYT5FW
CYT5FAV
CYTFAW
CYT5MV
CYT5MW
CYT5MPV
CYT5MPW
CYT5MFV
CYT5MFW CYT5MFAV CYT5MFAW
Fluorescence imaging
Brightfield imaging
Color brightfield imaging
Phase contrast imaging
           
       
Wide FOV camera
 
 
 
 
 
 
Filter-based fluorescence intensity
 
 
 
 
Filter-based fluorescence polarization
 
 
 
 
Filter-based time resolved fluorescence
 
 
 
 
Filter-based luminescence
 
     
Filter-based Alpha detection
 
 
 
 
 
 
 
 
Monochromator-based UV-Vis absorbance
       
Monochromator-based fluorescence intensity
       
Monochromator-based time resolved fluorescence (secondary)
       
Monochromator-based Luminescence
       
Take3 Plate compatible
       

Imaging Only and Multi-Mode Only Configurations

Part #
CYT5V
CYT5W
CYT5PV
CYT5PW CYT5MF CYT5MFA CYT5F CYT5FA CYT5M
Fluorescence imaging
 
       
Brightfield imaging
 
       
Color brightfield imaging
 
       
Phase contrast imaging
   
         
Wide FOV camera
 
 
         
Filter-based fluorescence intensity
 
 
 
 
 
Filter-based 
fluorescence polarization
 
 
 
 
 
Filter-based time resolved fluorescence
 
 
 
 
 
Filter-based luminescence
 
     
 
Filter-based Alpha detection
 
 
 
   
 
 
Monochromator-based UV-Vis absorbance
       
   
Monochromator-based Fluorescence intensity
       
   
Monochromator-based Time resolved fluorescence (secondary)
       
   
Monochromator-based Luminescence
       
   
Take3 Plate compatible
       
   

All configurations include incubation to 65 °C and shaking, and are compatible with BioTek’s Dual Reagent Injection Module, CO2/O2 Gas Controller, and BioStack Microplate Stacker, and BioSpa Automated Incubator.


Specifications:

General
Detection modes UV-Vis absorbance
Fluorescence intensity
Luminescence
Fluorescence polarization
Time-resolved fluorescence
Alpha
Read methods Endpoint, kinetic, spectral scanning, well area scanning
Microplate types Monochromator: 6- to 384-well plates
Filters: 6- to 1536-well plates
Imaging: 6- to 1536-well plates
Other labware supported Microscope slides, Petri and cell culture dishes, cell culture flasks (T25), counting chambers (hemocytometer)
Take3 Micro-Volume Plates
Temperature control 4-Zone incubation to 65 °C with Condensation Control;
+0.2 °C at 37 °C
Cooling Optional Peltier Cooling Module maintains internal temperature with < 1 °C rise over ambient. Provides rapid cooling after incubated processes.
Shaking Linear, orbital, double orbital
Software Gen5™ Microplate Reader and Imager Software
Gen5 Image+ and Image Prime software available for full image analysis
Gen5 Secure for 21 CFR Part 11 compliance (option)
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible
CO2 and O2 control (option) Range: 0 - 20% (CO2); 1 - 19% (O2)
Models for both CO2 and O2 or CO2 only are available
Imaging System
Imaging mode Fluorescence, brightfield, high contrast brightfield, color brightfield and phase contrast
Imaging method Single color, multi-color, montage, time lapse, z-stacking
Image processing Z-projection, digital phase contrast, stitching
Camera 16-bit Sony CMOS, standard or wide FOV
Objective capacity 6 user-replaceable objectives
Objectives available 1.25x, 2.5x (2.25x eff),2.5x (2.75x eff), 4x,10x, 20x, 40x, 60x
Phase objectives available 4x, 10x, 20x, 40x
Image filter cube capacity 4 user-replaceable fluorescence cubes plus brightfield channel
Imaging filter cubes available DAPI, CFP, GFP, YFP, RFP, Texas Red, CY5, CY7,Acridine Orange (ACR OR), CFP-YFP FRET, propidium,Iodide, chlorophyll, phycoerythrin, CY5.5, TagBFP, Alexa568, Ex377 / Em647
Imaging LED cubes available 365 nm, 390 nm, 465 nm, 505 nm, 523 nm, 590 nm, 623 nm, 655 nm, 740 nm
Automated functions Autofocus, auto LED intensity, auto exposure
Autofocus method Image-based autofocus
User-trained autofocus
Laser autofocus (option)
Positional controls Software control
Joystick control (option)
Image collection rate Image-based autofocus:
96 wells, 1 color (DAPI), 4x, 6 minutes
96 wells, 3 colors, 4x, 12 minutes

Laser autofocus:
96 wells, 1 color (DAPI), 4x, <3 minutes
96 wells, 3 colors, 4x, <7 minutes, 30 seconds
Burst Mode: 10 fps, single well, single color at <= 5Oms integration time
Image Analysis Software option Gen5 Image+: Advanced image analysis
Gen5 Image Prime: Advanced image analysis
Gen5 Secure Image+: Advanced image analysis, 21 CFR Part 11 features
Fluorescence Intensity
Light source Xenon flash
Detector PMT for monochromator system
PMT for filter system
Wavelength selection Quad monochromators (top/bottom)
Filters (top)
Wavelength range Monochromators: 250 - 700 nm (850 nm option)
Filters: 200 - 700 nm (850 nm option)
Monochromator bandwidth Variable, from 9 nm to 50 nm in 1 nm increments
Dynamic range 7 decades
Sensitivity Filters:
Fluorescein 0.25 pM (0.025 fmol/well, 384-well plate)

Quad Monochromator:
Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate) - top
Fluorescein 4 pM (0.4 fmol/well, 384-well plate) - bottom
Reading speed (kinetic) 96 wells: 11 seconds
384 wells: 22 seconds
Luminescence
Wavelength range 300 - 700 nm
Dynamic range >6 decades
Sensitivity Monos: 20 amol ATP (flash)
Filters: 10 amol ATP (flash), 100 amol (glow)
Fluorescence Polarization
Light source Xenon flash
Detector PMT
Wavelength selection Filters
Wavelength range 280 - 700 nm (850 nm option)
Sensitivity 1.2 mP standard deviation at 1 nM fluorescein
Time-Resolved Fluorescence
Light source Xenon flash
Detector PMT
Wavelength selection Quad monochromators (secondary mode)
Filters (top)
Wavelength range Filters: 200 - 700 nm (850 nm option)
Sensitivity Filters: Europium 40 fM (4 amol/well, 384-well plate)
Monos: Europium 1200 fM (120 amol/well, 384-well plate)
Absorbance
Light source Xenon flash
Detector photodiode
Wavelength selection Monochromator
Wavelength range 230 - 999 nm, 1 nm increment
Monochromator bandwidth 4 nm (230 - 285 nm), 8 nm (>285 nm)
Dynamic range 0 - 4.0 OD
Resolution 0.0001 OD
Pathlength correction yes
Monochromator wavelength accuracy +2 nm
Monochromator wavelength repeatability +0.2 nm
OD accuracy <1% at 2.0 OD
<3% at 3.0 OD
OD linearity <1% from 0 to 3.0 OD
OD repeatability <0.5% at 2.0 OD
Stray light 0.03% at 230 nm
Reading speed (kinetic) 96 wells: 11 seconds
384 wells: 22 seconds
Alpha Detection
Light source 100 mW 680 nm laser
Detector PMT
Wavelength selection Filters (top)
Sensitivity 100 amol LCK peptide (384-well low volume plate)
Reagent Injectors (option)
Supported detection modes All modes
Number 2 syringe pumps
Supported labware 6- to 384-well plates, Petri and cell culture dishes
Dead volume 1.1 mL with back flush
Dispense volume 5 - 1000 µL in 1 µL increments
Plate geometry 6- to 384-well microplates, Petri dishes
Dispense accuracy +1 µL or 2%
Dispense precision <2% at 50 - 200 µL
Physical Characteristics
Power 250 Watts maximum consumption.
Dimensions 20" D x 16.5" W x 17.5" H
(50.8 cm x 41.91 cm x 44.5 cm)
Weight 80 lbs (36.3 kg)
Regulatory
Regulatory CE and TUV marked. RoHS Compliant. Models for In Vitro Diagnostic use are available.