EL406 Washer Dispenser
Related Products
Compatible Products

BenchCel Microplate Handler
The Agilent BenchCel microplate handler is a compact, automated system that can be integrated to the MultiFlo FX multimode dispenser, EL406 washer dispenser, in addition to the 405 and ELx405 deep well washers, enabling automated workflows for a variety of applications. The BenchCel is compatible with a wide range of microplates including deep-well.

BioSpa 8 Automated Incubator
BioSpa 8 is an automated incubator linking BioTek readers or imagers together with washers and dispensers for full workflow automation of up to 8 microplates. Temperature, CO2/O2 and humidity levels are controlled and monitored through the BioSpa software to maintain an ideal environment for cell cultures during all experimental stages.

BioStack Microplate Stacker
BioStack is a compact and versatile microplate stacker compatible with BioTek’s washers, dispensers, detectors and imaging systems. BioStack offers rapid plate exchange speeds to increase throughput and enhance productivity, accommodating assay workflows both with and without plate lids. BioStack models equipped with a rotational gripper allow ergonomically friendly instrument panel access and compact integration positioning
Software
The EL406 has extensive onboard software, with an intuitive menu-driven interface. Program all aspects of the system’s dispense, wash and maintenance parameters, quickly and easily. Up to 75 programs can be stored onboard.
LHC Software allows computer-based programming of multi-step processes and it is used for integrating BioTek’s multi-mode washer dispensers, washers and dispensers into robotic systems. You can operate the system under computer control via LHC, or create protocols in LHC and download to the instrument for recall and execution.
LHC Secure software offers features to facilitate compliance to FDA directive 21 CFR Part 11 with computer control of BioTek’s Multi-Mode Washer Dispensers, Washers and Dispensers.
LHC SiLA software driver enables BioTek washer and dispenser integration into SiLA compliant automated systems. Includes LHC software for computer control and third party integration of BioTek’s Multi-Mode Washer Dispensers, Washers and Dispensers.
Gen5 and LHC Sample Files
Agilent BioTek Gen5 and LHC software are used to drive the range of Agilent BioTek microplate readers, imagers and liquid handling devices. Below you will find a current list of sample files for both Gen5 and LHC. These sample files include Gen5 experiment (.xpt) and protocol (.prt) files as well as LHC protocol (.lhc) files. Plate definition, filter cube and imaging objective files (.xml) are also listed below for use in Gen5. Expand the section you are interested in and click on the link to directly download the relevant file.
Accessories
Adapters and Labware Holders
- 4032066Wire bottle holder
- 6002076Holder for PCR Microplates
Benchcel Integration Kits
BioStack Integration Kits
Bottles & Tubing
- 1173003Spare Cap for 4L Dispense Bottle
- 7100531Cap for Waste Bottle, 4L (Also fits 10L or 20L)
- 7100534Waste Bottle, 4L
- 7100543SWaste Set with Level Sensing, 4L Bottles
- 7100544Cap for Waste Bottle with Level Sensing, 4L
- 7100556Waste Bottle and Tubing, 20L
- 7100557Waste Bottle and Tubing, 10L
- 7100559Dispense Bottle (10L)
- 7180541Spare syringe pump dispense tubing and check valve kit, Teflon-lined, DMSO and acetonitrile compatible (non-autoclavable, but compatible with the autoclavable syringe module hardware)
- 7183002Spare syringe pump dispense tubing and check valve kit (7183002)
- 7183006Spare syringe pump dispense tubing and check valve kit, autoclavable
Cassettes
- 7170007 Large Volume Replacement Tubing Set (10 µL) - molded plastic tips
- 7170008Medium Volume Replacement Tubing Set (5 µL) - molded plastic tips
- 7170009Low Volume Replacement Tubing Set (1 µL) - molded plastic tips
- 7170010Large Volume (10 µL) Cassette - molded plastic tips
- 7170011Medium Volume (5 µL) Cassette - molded plastic tips
- 7170012500 nL – 50 µL, 1 µL increments, cassette, plastic tips
- 7170013Large Volume (10 µL) Cassette - stainless steel tips
- 7170014Medium Volume (5 µL) Cassette - stainless steel tips
- 7170015500 nL – 50 µL, 1 µL increments, cassette, sapphire jeweled stainless steel tips
- 7170016500 nL - 50 µL, 1 µL increments, 1536-well cassette, sapphire jeweled steel tips
- 7170018 500 nL - 50 µL, 1 µL increments, 1536-well cassette, plastic tips
- 7170020Large volume (10 µL) Cassette Tubing Extension Kit
- 7170021Medium volume (5 µL) Cassette Tubing Extension Kit
- 7170022Low volume (1 µL) Cassette Tubing Extension Kit
- 7170023Large Volume (10 µL) Cassette - large bore, molded plastic tips
- 7170024Medium Volume (5 µL) Cassette - large bore, molded plastic tips
- 7170026Medium volume replacement tubing set (5 µL) – molded plastic large bore tips
- 7170029Replacement plastic tips for peripump 10 µl cassette 10 µl
- 7170030Replacement plastic tips, large bore, for peripump 10 µl cassette
Dispense/Waste Systems
- 68105Standard Silencing muffler for high-flow vacuum pump
- 1170530Complete Dispense/Waste System 115V/230V, 4L Bottles
- 1170560Complete Direct Drain Waste System 115V/230V, 4L Bottles
- 1170561Direct Drain Waste System Upgrade Kit 115V/230V, 4L Bottles
- 1170562Complete Direct Drain High Flow Waste System 115V/230V, 4L Bottles
- 7100581SDispense System Complete Assembly, 10L
- 7100582SVacuum Set with Level Sense Assembly, 10L
- 7100746SComplete Waste System 115V/230V, 4L Bottles
- 7100751Complete Dispense/High Flow Waste System 115V/230V, 4L Bottles (7100751)
- 7100752Complete Dispense/High Flow Waste System 115/230V, 10L Bottles
- 7100753SComplete High Flow Waste System 115V/230V, 4L Bottles
- 7100754High Flow Vacuum Pump 115/230V
- 7100763Complete Dispense/High Flow Waste System 115V/230V, 20L bottles
- 7103035Standard Vacuum Pump 115V/230V
Filters
Manifolds
- 7180507SSyringe dispenser manifold, 16-channel, straight tubes, for 96/384 well plates
- 7180533SSyringe dispenser manifold, small bore tubes, for 1536 well plates
- 7180534SSyringe dispenser manifold, large bore tubes, for 1536 well plates
- 7180543SSyringe Dispenser Manifold, 96-/384-well Plates - 1x16-tube, Autoclavable
- 7180548SSyringe Dispenser Manifold, 96-/384-well Plates - 2x8-tube, Non-Autoclavable
- 7180549S8-tube (1x8) Large bore manifold for 96-well Microplates autoclavable
- 7180552SSyringe Dispenser Manifold, 1536-well Plates - 1x32-tube Large Bore, Autoclavable
- 7180553SSyringe Dispenser Manifold, 1536-well Plates - 1x32-tube Small Bore, Autoclavable
- 7180560SSyringe Dispenser Manifold, 96-/384-well Plates - 2x8-tube, Autoclavable
Miscellaneous
- 01112Standard Silencing Muffler for Standard Vacuum Pump
- 01113Silencing Muffler for Standard Vacuum Pump
- 4030551Vacuum Gauge/Regulator
- 7100025SStylus Kit for any 405/ELx405 Select Deep Well manifold
- 710009615' extension kit for use with robotic system integrations of Elx405 Select Deep Well, EL406
- 7102215384-well Ring Magnet
- 710221696-well Ring Magnet
- 710301696-well Flat Magnet
- 7103017384-well Flat Magnet
- 7180006S2 Syringe Pump Dispenser Module - Autoclavable Upgrade Kit
- 7180010Peristaltic Pump Angled Dispense Kit
- 7180011Magnet Adapter Kit
- 7180029EL406 Vacuum Filtration Module Accessory
- 7182042Mist shield for EL406
- 718210940 mL Capacity Dispenser Priming Trough
- 7210509Spare Reservoir Holder and Strap