product design

Synergy Neo2 Hybrid Multi-Mode Reader

Specifications

General

Detection modes UV-Vis absorbance
Fluorescence intensity
Luminescence
Fluorescence polarization
Time-resolved fluorescence
Alpha
Read methods Endpoint, kinetic, spectral scanning, well area scanning
Microplate types 6- to 1536-well plates
Other labware supported Petri and cell culture dishes
Take3 Micro-Volume Plates
Temperature control 4-Zone incubation to 65 °C with Condensation Control™
+0.2 °C at 37 °C
Shaking Linear, orbital, double orbital
Software Gen5™ Microplate Reader and Imager Software
Gen5 Secure for 21 CFR Part 11 compliance (option)
Automation BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible
CO2 and O2 control (option) Range: 0 - 20% (CO2); 1 - 19% (O2)
Control Resolution: + 0.1% (CO2 and O2)
Stability: +0.2% at 5% CO2; +0.2%at 1% O2
Models for CO2 /O2 or CO2 only are available
Barcode reader 1D and 2D camera-based scanner

Absorbance

Light source Xenon flash
Detector photodiode
Wavelength selection monochromator
Wavelength range 230 - 999 nm, 1 nm increments
Monochromator bandwidth 2 nm (230-285 nm), 4 nm (>285 nm)
Dynamic range 0 - 4.0 OD
Resolution 0.0001 OD
Pathlength correction yes
Monochromator wavelength accuracy +2 nm
Monochromator wavelength repeatability +0.2 nm
OD accuracy <1% at 2.0 OD
<3% at 3.0 OD
OD linearity <1% from 0 to 3.0 OD
OD repeatability <0.5% at 2.0 OD
Stray light 0.03% at 230 nm
Reading speed (kinetic) 96 well: 6 seconds
384 well: 11 seconds
1536 well: 25 seconds

Fluorescence Intensity

Light source Xenon flash
Detector Dual top PMTs
Single top PMT (option)
Low noise PMT (bottom filter system)
Red shifted PMT (top/bottom monochromator system)
Wavelength selection Quad monochromators (top/bottom)
Filters (top/bottom)
Wavelength range Monochromators: 250 - 850 nm
Filters (dual PMT): 200 - 850 nm
Monochromator bandwidth Variable, from 3 to 50 nm in 1 nm increments
Dynamic range 7 decades
Sensitivity Filters:
Fluorescein 0.2 pM (4 amol/well, 20 µL, 384-well low volume plate) - top
Fluorescein 1 pM (10 amol/well, 10 µL, 1536-well plate) - top
Fluorescein 1 pM (0.1 fmol/well, 100 µL, 384-well plate) - bottom

Quad monochromator:
Fluorescein 2 pM (40 amol/well, 20 µL, 384-well low volume plate) - top
Fluorescein 2.5 pM (0.25 fmol/well, 100 µL, 384-well plate) - bottom
Reading speed (kinetic) 96 well: 6 seconds
384 well: 11 seconds
1536 well: 25 seconds

Luminescence

Wavelength range 300 - 700 nm
Dynamic range > 6 decades
Sensitivity 5 amol ATP typical (384-well low volume plate)

Fluorescence Polarization

Light source Xenon flash
Detector Dual PMT or single PMT (option)
Wavelength selection Filters
Wavelength range 280 - 850 nm
Sensitivity 1 mP standard deviation at 1 nM fluorescein
(384-well low volume plate)
1.5 mP standard deviation at 1 nM fluorescein (1536-well plate)

Time-Resolved Fluorescence

Light source Xenon flash
Detector Dual PMT or single PMT (option)
Wavelength selection Quad monochromators (top/bottom)
Filters (top/bottom)
Wavelength range Monos: 250 - 850 nm
Filters (dual PMT): 200 - 850 nm
Sensitivity Europium 40 fM (384-well low volume plate)
Europium 70 fM (1536-well plate)

Alpha Detection

Light source 100 mW 680 nm laser
Detector PMT
Wavelength selection Filters (top)
Sensitivity 100 amol LCK peptide (384-well low volume plate)
Read speed 96 well: 30 seconds
384 well: 1 minute 50 seconds
1536 well: 7 minutes 20 seconds

Reagent Dispensers

Supported detection modes All modes
Number 2 syringe pumps
Supported labware 6- to 384-well plates, Petri dishes
Dead volume 1.1 mL with back flush
Dispense volume 5 - 1000 µL in 1 µL increments
Dispense accuracy + 1 µL or 2%
Dispense precision < 2% at 50-200 µL

Physical Characteristics

Power 250 Watts max.
Dimensions 15.4" W x 20.7" D x 16.1" H
(39 x 52.5 x 41 cm)
Weight 78 lbs (35 kg)

Regulatory

Regulatory CE and TUV marked. RoHS Compliant. Models for In Vitro Diagnostic use are available.

Specifications are subject to change. Performance values represent the average observed factory test values.

link