var product_options = {"136":{"pid":"136","name":"BioStack™ Microplate Stacker","configurable":"Yes","category":"Automation","models":[{"id":"49","model_name":"BIOSTACK"}],"features":[{"id":"8","name":"30 standard height microplates per stack","more":""},{"id":"9","name":"Automatic restacking capability","more":""},{"id":"10","name":"Presents/receives microplates in landscape orientation","more":""},{"id":"11","name":"Adds stacking capabilities to range of BioTek detection and liquid handling systems","more":""}],"upsells":[],"options":[{"id":"10","name":"ELx405 Integration Kit","more":"","category":"Integration","append":"7310010"},{"id":"11","name":"µFill Integration Kit","more":"","category":"Integration","append":"7310012"},{"id":"12","name":"NanoQuot Integration Kit","more":"","category":"Integration","append":"7150001"},{"id":"13","name":"Precision Integration Kit","more":"","category":"Integration","append":"7110004"},{"id":"14","name":"PowerWave HT/XS Integration Kit","more":"","category":"Integration","append":"7310011"},{"id":"15","name":"Synergy 2 Integration Kit","more":"","category":"Integration","append":"7310010"},{"id":"16","name":"Synergy HT Integration Kit","more":"","category":"Integration","append":"7310009"}],"include":{"10":[""],"11":[""],"12":[""],"13":[""],"14":[""],"15":[""],"16":[""]},"exclude":{"10":["11,12,13,14,15,16"],"11":["10,12,13,14,15,16"],"12":["10,11,13,14,15,16"],"13":["10,11,12,14,15,16"],"14":["10,11,12,13,15,16"],"15":["10,11,12,13,14,16"],"16":["10,11,12,13,14,15"]},"configs":{"49":{"model_id":"49","options":"14"}},"conf_list":"16|BIOSTACK||15|BIOSTACK||13|BIOSTACK||11|BIOSTACK||10|BIOSTACK||14|BIOSTACK||12|BIOSTACK||14|BIOSTACK"},"146":{"pid":"146","name":"BioStack™ Microplate Storage System","configurable":"Yes","category":"Automation","models":[{"id":"125","model_name":"BIOSTACKPR"}],"features":[{"id":"26","name":"30 standard height microplates per stack","more":""},{"id":"27","name":"Automatic restacking capability","more":""},{"id":"28","name":"Presents/receives microplates in landscape orientation","more":""},{"id":"29","name":"Adds storage to established automation processes with 3rd party instrumentation","more":""},{"id":"30","name":"Includes ActiveX Programmer’s Package","more":""}],"upsells":[],"options":[],"include":[],"exclude":[],"configs":{"125":{"model_id":"125","options":""}},"conf_list":"|BIOSTACKPR"},"145":{"pid":"145","name":"BioStack™ Twister® II Microplate Handler","configurable":"Yes","category":"Automation","models":[{"id":"175","model_name":"BIOSTACKTII"}],"features":[{"id":"31","name":"Up to 320 standard height microplates","more":""},{"id":"32","name":"340° axis of rotation with telescoping arm and rotational gripper","more":""},{"id":"33","name":"Automatic restacking capability","more":""},{"id":"34","name":"Includes iLink PC software with setup wizard","more":""},{"id":"35","name":"Handles microplates in portrait and landscape orientation","more":""},{"id":"36","name":"Adds stacking capabilities to range of BioTek detection and liquid handling systems","more":""},{"id":"37","name":"Handles de-lidding, pipette tip racks and variable microplate heights","more":""}],"upsells":[],"options":[{"id":"30","name":"ELx405 Integration Kit","more":"","category":"Integration","append":"48632"},{"id":"31","name":"µFill Integration Kit","more":"","category":"Integration","append":"48635"},{"id":"32","name":"NanoQuot Integration Kit","more":"","category":"Integration","append":""},{"id":"33","name":"Precision Integration Kit","more":"","category":"Integration","append":"48633"},{"id":"34","name":"Gen5 Integration Kit","more":"PowerWave Microplate Spectrophotometer, Synergy 2 Microplate Multi-Detection Reader, Synergy HT Microplate Multi-Detection Reader.","category":"Integration","append":"48653"},{"id":"35","name":"KC4 Integration Kit","more":"PowerWave Microplate Spectrophotometer, Synergy HT Microplate Multi-Detection Reader, Clarity Microplate Luminescence Reader.","category":"Integration","append":"48634"}],"include":{"30":[""],"31":[""],"32":[""],"33":[""],"34":[null],"35":[""]},"exclude":{"30":[""],"31":[""],"32":[""],"33":[""],"34":[null],"35":[""]},"configs":{"175":{"model_id":"175","options":"34"}},"conf_list":"30|BIOSTACKTII||30|BIOSTACKTII||31|BIOSTACKTII||32|BIOSTACKTII||33|BIOSTACKTII||35|BIOSTACKTII||34|BIOSTACKTII"},"143":{"pid":"143","name":"Clarity™ Luminescence Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"121","model_name":"CLARITYPC"},{"id":"122","model_name":"CLARITY2PC"},{"id":"123","model_name":"CLARITYHTI2PC"},{"id":"165","model_name":"CLARITY1PC"},{"id":"215","model_name":"CLARITYCUSTOM"}],"features":[{"id":"86","name":"Luminescence in 96-well plates","more":""},{"id":"87","name":"Shaking","more":""},{"id":"88","name":"Clarity PC software","more":""},{"id":"89","name":"Gen5 Data Analysis software","more":""},{"id":"122","name":"3rd party automation compatible","more":""},{"id":"123","name":"Clarity PC software","more":""}],"upsells":[{"id":"22","name":"Gen5 Secure software","more":"For 21 CFR Part 11 compliance","category":"Software","append":"GEN5SECURE"}],"options":[{"id":"82","name":"Temperature Control to 42°C and Luminescence in 96 and 384-well plates","more":"","category":"Hardware","append":""},{"id":"83","name":"Single reagent dispenser","more":"","category":"Hardware","append":""},{"id":"84","name":"Dual reagent dispenser","more":"","category":"Hardware","append":""},{"id":"124","name":"Custom configuration","more":"Custom configurations are available (more than two reagent dispensers and combinations not available through this page). Check this option to receive more information.","category":"Hardware","append":""}],"include":{"82":["84"],"83":[""],"84":[""],"124":[""]},"exclude":{"82":["83"],"83":["82,84"],"84":["83"],"124":["82,83,84"]},"configs":{"121":{"model_id":"121","options":""},"122":{"model_id":"122","options":"84"},"165":{"model_id":"165","options":"83"},"123":{"model_id":"123","options":"82,84"},"215":{"model_id":"215","options":"124"}},"conf_list":"|CLARITYPC||84|CLARITY2PC||83|CLARITY1PC||82,84|CLARITYHTI2PC||124|CLARITYCUSTOM"},"62":{"pid":"62","name":"ELx405™ Microplate Washer","configurable":"Yes","category":"Liquid Handling","models":[{"id":"109","model_name":"ELx405HTS"},{"id":"110","model_name":"ELx405HTVS"},{"id":"29","model_name":"ELx405U"},{"id":"30","model_name":"ELx405UV"},{"id":"31","model_name":"ELx405R"},{"id":"32","model_name":"ELx405VR"},{"id":"33","model_name":"ELx405MR"},{"id":"34","model_name":"ELx405MVR"},{"id":"85","model_name":"ELx405HT"},{"id":"86","model_name":"ELx405HTV"},{"id":"95","model_name":"ELx405UCW"},{"id":"111","model_name":"ELx405UCWS"},{"id":"112","model_name":"ELx405UCWVS"},{"id":"113","model_name":"ELx405US"},{"id":"114","model_name":"ELx405UVS"},{"id":"115","model_name":"ELx405RS"},{"id":"116","model_name":"ELx405VRS"},{"id":"117","model_name":"ELx405HT2"},{"id":"118","model_name":"ELx405HTV2"},{"id":"119","model_name":"ELx405HT2S"},{"id":"120","model_name":"ELx405HTV2S"}],"features":[{"id":"3","name":"Extensive onboard software","more":""},{"id":"4","name":"Easy maintenance with selection of pre-programmed routines","more":""},{"id":"5","name":"Fluid detection, fluid flow and vacuum sensors for complete protection during unattended operations","more":""},{"id":"6","name":"Bio-Stack compatible","more":""},{"id":"7","name":"3rd Party automation compatible","more":"ELx405 washers can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details."}],"upsells":[{"id":"52","name":"Liquid Handling Control Software","more":"","category":"Software","append":"LHC405"},{"id":"1","name":"Bio-Stack Microplate Stacker","more":"ELx405 Washers can be automated with the Bio-Stack for processing up to 30 standard height plates","category":"Automation","append":""},{"id":"2","name":"Bio-Stack Twister II Microplate Handler","more":"ELx405 Washers can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates.","category":"Automation","append":""}],"options":[{"id":"1","name":"Cell Washing","more":"","category":"Hardware","append":""},{"id":"2","name":"Magnetic particle protocols","more":"","category":"Hardware","append":""},{"id":"3","name":"384-well plate washing only, 192-channel manifold","more":"192-channel patented Dual-Action manifold with separate dispense/aspiration","category":"Hardware","append":""},{"id":"4","name":"96- and 384-well plate washing, 96-channel manifold","more":"96-channel patented Dual-Action manifold with separate dispense/aspiration","category":"Hardware","append":""},{"id":"5","name":"96- and 384-well plate washing, 96- and 192-channel manifold","more":"96- and 192-channel patented Dual-Action manifold with separate dispense/aspiration","category":"Hardware","append":""},{"id":"6","name":"Automatic buffer switching for up to 4 wash buffers/rinse solutions","more":"","category":"Hardware","append":""},{"id":"7","name":"Ultrasonic Advantage™ built-in ultrasonic cleaner","more":"","category":"Hardware","append":""}],"include":{"1":["4"],"2":[""],"3":[""],"4":[""],"5":[""],"6":[null],"7":[null]},"exclude":{"1":["2,3,5"],"2":["1,3,4,5,7"],"3":["1,4,5"],"4":["3,5"],"5":["1,3,4"],"6":[null],"7":[null]},"configs":{"85":{"model_id":"85","options":"3"},"117":{"model_id":"117","options":"5"},"119":{"model_id":"119","options":"5,7"},"109":{"model_id":"109","options":"3,7"},"86":{"model_id":"86","options":"5,6"},"118":{"model_id":"118","options":"5,6"},"120":{"model_id":"120","options":"5,6,7"},"110":{"model_id":"110","options":"3,6,7"},"33":{"model_id":"33","options":"2"},"34":{"model_id":"34","options":"2,6"},"31":{"model_id":"31","options":""},"115":{"model_id":"115","options":"7"},"29":{"model_id":"29","options":"4"},"95":{"model_id":"95","options":"1,4"},"111":{"model_id":"111","options":"1,4,7"},"112":{"model_id":"112","options":"1,4,6,7"},"113":{"model_id":"113","options":"4,7"},"30":{"model_id":"30","options":"4,6"},"114":{"model_id":"114","options":"4,6,7"},"32":{"model_id":"32","options":"6"},"116":{"model_id":"116","options":"6,7"}},"conf_list":"3|ELx405HT||5|ELx405HT2||5,7|ELx405HT2S||3,7|ELx405HTS||3,6|ELx405HTV||5,6|ELx405HTV||5,6|ELx405HTV2||5,6,7|ELx405HTV2S|||ELx405HTV2S||5,6,7|ELx405HTV2S||3,6,7|ELx405HTVS|||ELx405HTVS||3,6,7|ELx405HTVS||2|ELx405MR||2,6|ELx405MVR|||ELx405R||7|ELx405RS||4|ELx405U||1,4|ELx405UCW||1,4,7|ELx405UCWS||1,4,7|ELx405UCWS||1,4,6,7|ELx405UCWVS||4,7|ELx405US||4,6|ELx405UV||4,6,7|ELx405UVS||6|ELx405VR||6,7|ELx405VRS|||ELx405HTS||3,7|ELx405HTS||3,7|ELx405HTS||1,4,6,7|ELx405UCWVS||2|ELx405MR|||ELx405R||2|ELx405MR|||ELx405R"},"47":{"pid":"47","name":"ELx50™ Microplate Strip Washer","configurable":"Yes","category":"Liquid Handling","models":[{"id":"35","model_name":"ELx50/16"},{"id":"36","model_name":"ELx50/16V"},{"id":"37","model_name":"ELx50/8"},{"id":"38","model_name":"ELx50/8V"},{"id":"39","model_name":"ELx50/12"},{"id":"40","model_name":"ELx50/12V"},{"id":"216","model_name":"ELX50/8FMW"}],"features":[{"id":"12","name":"96-well plate washing","more":""},{"id":"13","name":"Extensive onboard software","more":"Independent control of plate position and fully programmable fluid volumes, flow rates, shaking and soaking."},{"id":"14","name":"Easy maintenance with selection of pre-programmed routines","more":""},{"id":"15","name":"Syringe drive fluid-delivery system","more":""},{"id":"16","name":"Unique priming trough built into removable microplate carrier","more":""}],"upsells":[],"options":[{"id":"17","name":"96- and 384-well microplate, 1x16 and 1x8 strip washing","more":"16-channel patented Dual-Action manifold with separate dispense/aspiration","category":"Hardware","append":""},{"id":"18","name":"96-well microplate, 1x8 strip washing","more":"8-channel dispense/aspiration manifold","category":"Hardware","append":""},{"id":"19","name":"96-well microplate, 1x12 strip washing","more":"12-channel dispense/aspiration manifold","category":"Hardware","append":""},{"id":"20","name":"Automatic buffer switching for up to 3 wash buffers/rinse solutions","more":"","category":"Hardware","append":""},{"id":"125","name":"96-well microplate, vacuum filtration option for filter bottom plates","more":"Also accommodates 96-well solid bottom plates and 1x8 strips for conventional ELISAs and cell-based assays","category":"Hardware","append":""}],"include":{"17":[""],"18":[""],"19":[""],"20":[null],"125":[""]},"exclude":{"17":["18,19"],"18":["17,19"],"19":["17,18"],"20":[null],"125":["17,18,19,20"]},"configs":{"37":{"model_id":"37","options":"18"},"38":{"model_id":"38","options":"18,20"},"39":{"model_id":"39","options":"19"},"40":{"model_id":"40","options":"19,20"},"35":{"model_id":"35","options":"17"},"36":{"model_id":"36","options":"17,20"},"216":{"model_id":"216","options":"125"}},"conf_list":"18|ELx50/8||18,20|ELx50/8V||19|ELx50/12||19,20|ELx50/12V||17|ELx50/16||17,20|ELx50/16V||125|ELX50/8FMW||17|ELx50/16||17,20|ELx50/16V||17|ELx50/16||17,20|ELx50/16V||18|ELx50/8||18,20|ELx50/8V||19|ELx50/12||19,20|ELx50/12V"},"21":{"pid":"21","name":"ELx800™ Absorbance Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"26","model_name":"ELx800"},{"id":"27","model_name":"ELx800NB"},{"id":"28","model_name":"ELx800UV"}],"features":[{"id":"106","name":"Absorbance detection","more":""},{"id":"79","name":"6- through 96- well plate reading","more":""},{"id":"80","name":"400 nm to 750 nm wavelength range","more":""},{"id":"81","name":"5-filter position wheel","more":""},{"id":"82","name":"0n-Board software with 55 programmable assays","more":""}],"upsells":[{"id":"16","name":"Gen5 Software","more":"","category":"Software","append":"GEN5"},{"id":"17","name":"Gen5 Secure Software","more":"Gen5 Secure provides features for compliance to 21 CFR Part 11","category":"Software","append":"GEN5SECURE"},{"id":"18","name":"Gen5 ELISA","more":"","category":"Software","append":"GEN5ELISA"}],"options":[{"id":"72","name":"6- to 384- well plate reading","more":"","category":"Hardware","append":""},{"id":"73","name":"340 nm to 750 nm wavelength range","more":"","category":"Hardware","append":""}],"include":{"72":[""],"73":[""]},"exclude":{"72":["73"],"73":["72"]},"configs":{"26":{"model_id":"26","options":""},"27":{"model_id":"27","options":"72"},"28":{"model_id":"28","options":"73"}},"conf_list":"77|ELx800||73,77|ELx800NB||72,77|ELx800UV||73|ELx800NB||72|ELx800UV||72|ELx800|||ELx800||72|ELx800|||ELx800|||ELx800||72|ELx800||73|ELx800|||ELx800||72|ELx800UV||73|ELx800NB||72|ELx800NB||73|ELx800UV"},"22":{"pid":"22","name":"ELx808™ Absorbance Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"22","model_name":"ELx808"},{"id":"24","model_name":"ELx808IU"}],"features":[{"id":"70","name":"96- well plate reading","more":""},{"id":"71","name":"380 nm to 900 nm wavelength range","more":""},{"id":"72","name":"6-filter position wheel","more":""},{"id":"73","name":"Programmable shaking","more":""},{"id":"74","name":"0n-Board software with 55 programmable assays","more":""},{"id":"103","name":"Absorbance detection","more":""}],"upsells":[{"id":"13","name":"Gen5 Software","more":"","category":"Software","append":""},{"id":"14","name":"Gen5 Secure software","more":"Gen5 Secure provides features for compliance to 21 CFR Part 11","category":"Software","append":""},{"id":"15","name":"Gen5 ELISA","more":"","category":"Software","append":""}],"options":[{"id":"61","name":"Temperature control to 50ºC and 340 nm to 900 nm wavelength range","more":"","category":"Hardware","append":""}],"include":{"61":[""]},"exclude":{"61":[""]},"configs":{"22":{"model_id":"22","options":""},"24":{"model_id":"24","options":"61"}},"conf_list":"66|ELx808||61,62,66|ELx808IU|||ELx808|||ELx808IU||61,62|ELx808IU||61,62|ELx808|||ELx808|||ELx808IU||61,62|ELx808IU||61|ELx808IU|||ELx808||61|ELx808IU|||ELx808||61|ELx808IU"},"117":{"pid":"117","name":"FLx800™ Fluorescence Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"1","model_name":"FLx800T"},{"id":"3","model_name":"FLx800TB"},{"id":"4","model_name":"FLx800TBI"},{"id":"7","model_name":"FLx800TBID"},{"id":"105","model_name":"FLx800TBP"}],"features":[{"id":"102","name":"Fluorescence Intensity Top","more":""},{"id":"101","name":"Luminescence","more":""},{"id":"100","name":"On-Board reader control and data analysis software","more":""},{"id":"124","name":"Gen5 included with temperature control and dispenser features","more":""},{"id":"125","name":"6- to 384-well microplates","more":""}],"upsells":[{"id":"24","name":"Gen5 ELISA","more":"","category":"Software","append":""},{"id":"25","name":"Gen5","more":"","category":"Software","append":""},{"id":"26","name":"Gen5 Secure for 21 CFR part 11 compliance","more":"","category":"Software","append":""}],"options":[{"id":"98","name":"Bottom Reading","more":"","category":"Detection Mode","append":""},{"id":"95","name":"PCR plate reading capability","more":"This configuration provides more vertical clearance in the reading chamber to accommodate PCR plates that are often taller than regular microplates. This option is not compatible with the temperature control or reagent dispensing option.","category":"Hardware","append":""},{"id":"96","name":"Temperature control to 50°C and Shaking","more":"","category":"Hardware","append":""},{"id":"97","name":"Single Reagent Dispenser","more":"","category":"Hardware","append":""}],"include":{"98":[null],"95":["98"],"96":["98"],"97":["96,98"]},"exclude":{"98":[null],"95":["96,97"],"96":[""],"97":["95"]},"configs":{"1":{"model_id":"1","options":""},"3":{"model_id":"3","options":"98"},"4":{"model_id":"4","options":"98,96"},"7":{"model_id":"7","options":"98,96,97"},"105":{"model_id":"105","options":"98,95"}},"conf_list":"|FLx800T||98|FLx800TB||96,98|FLx800TBI||96,97,98|FLx800TBID||95,98|FLx800TBP|||FLx800T||98,95|FLx800TBP||98,96,97|FLx800TBID||98,96|FLx800TBI||98,95|FLx800TBP||98,95|FLx800TBP||98,96|FLx800TBI||98,96,97|FLx800TBID"},"149":{"pid":"149","name":"Gen5™ Data Analysis Software","configurable":"Yes","category":"Software","models":[{"id":"242","model_name":"GEN5CL"},{"id":"132","model_name":"GEN5"},{"id":"133","model_name":"GEN5SECURE"},{"id":"134","model_name":"GEN5ELISA"},{"id":"135","model_name":"GEN5RC"}],"features":[{"id":"108","name":"For applications in absorbance, fluorescence and luminescence","more":""},{"id":"109","name":"StepWise™ tools","more":""}],"upsells":[],"options":[{"id":"99","name":"Compliance to the FDA directive 21 CFR Part 11","more":"","category":"Other","append":""},{"id":"100","name":"Reader control and data analysis for endpoint ELISA assays","more":"","category":"Other","append":""},{"id":"101","name":"Control of plate reader, data collection and report/export options only","more":"","category":"Other","append":""},{"id":"140","name":"PC-based interface for BioTek\'s ELx800 and ELx808 microplate readers","more":"","category":"Other","append":""}],"include":{"99":[""],"100":[""],"101":[""],"140":[""]},"exclude":{"99":["100,101,140"],"100":["99,101,140"],"101":["99,100,140"],"140":["99,100,101"]},"configs":{"132":{"model_id":"132","options":""},"133":{"model_id":"133","options":"99"},"134":{"model_id":"134","options":"100"},"135":{"model_id":"135","options":"101"},"242":{"model_id":"242","options":"140"}},"conf_list":"|GEN5||99|GEN5SECURE||100|GEN5ELISA||101|GEN5RC||140|GEN5CL"},"58":{"pid":"58","name":"LabRack","configurable":"Yes","category":"Accessories","models":[{"id":"66","model_name":"LabRack"}],"features":[{"id":"107","name":"Sturdy rack for stacking reader, washer, printer, laptop, etc.","more":""}],"upsells":[{"id":"35","name":"5" Extension Tube","more":"Extends shelf height of LabRack by 5\"","category":"Other","append":"48398"},{"id":"36","name":"12" Extension Tube","more":"Extends shelf height of LabRack by 12\"","category":"Other","append":"48399"}],"options":[],"include":[],"exclude":[],"configs":{"66":{"model_id":"66","options":""}},"conf_list":"|LabRack"},"155":{"pid":"155","name":"Liquid Handling Control™ Software","configurable":"Yes","category":"Software","models":[{"id":"238","model_name":"LHC405"},{"id":"239","model_name":"LHCMFS"}],"features":[{"id":"159","name":"StepWise™ tools","more":""}],"upsells":[],"options":[{"id":"136","name":"For use with ELx405 Microplate Washer","more":"","category":"Other","append":""},{"id":"137","name":"For use with MicroFlo Select Dispenser","more":"","category":"Other","append":""}],"include":{"136":[""],"137":[""]},"exclude":{"136":["137"],"137":["136"]},"configs":{"238":{"model_id":"238","options":"136"},"239":{"model_id":"239","options":"137"}},"conf_list":"136|LHC405||137|LHCMFS"},"130":{"pid":"130","name":"MicroFill™ Microplate Dispenser","configurable":"Yes","category":"Liquid Handling","models":[{"id":"43","model_name":"AF1000"},{"id":"44","model_name":"AF1000A"}],"features":[{"id":"38","name":"96- and 384-well standard, half height and deep well microplates","more":""},{"id":"39","name":"Microprocessor-controlled syringe pump guarantees optimal dispense performance with no recalibration","more":""},{"id":"40","name":"Extensive onboard software – fully programmable plate position during dispense, fluid volumes, flow rates and soaking","more":""},{"id":"41","name":"Easy maintenance with selection of pre-programmed routines","more":""},{"id":"42","name":"3rd party automation compatible","more":"μFill dispensers can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details."},{"id":"110","name":"Bio-Stack compatible","more":""}],"upsells":[{"id":"37","name":"96-well half-area and/or PCR microplates, 8-channel dispense manifold (NOTE: only available with Model AF1000A)","more":"","category":"Other","append":"7140515S"},{"id":"38","name":"24-well microplates, 8-channel dispense manifold (NOTE: only available with Model AF1000A)","more":"","category":"Other","append":"7140518S"},{"id":"39","name":"Organic solvent compatibility – DMSO and Acetonitrile (NOTE: only available with Model AF1000A)","more":"","category":"Other","append":"7140514"},{"id":"5","name":"Bio-Stack Microplate Stacker","more":"μFill dispensers can be automated with the Bio-Stack for processing up to 30 standard height plates.","category":"Automation","append":""},{"id":"6","name":"Bio-Stack Twister II Microplate Handler","more":"μFill dispensers can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates","category":"Automation","append":""}],"options":[{"id":"36","name":"Autoclavable fluid path for guaranteed sterility, 16-channel dispense manifold","more":"","category":"Hardware","append":""}],"include":{"36":[null]},"exclude":{"36":[null]},"configs":{"43":{"model_id":"43","options":""},"44":{"model_id":"44","options":"36"},"156":{"model_id":"156","options":"36,37"},"157":{"model_id":"157","options":"36,37,38"},"158":{"model_id":"158","options":"36,37,38,39"},"159":{"model_id":"159","options":"36,38"},"160":{"model_id":"160","options":"36,38,39"},"161":{"model_id":"161","options":"36,39"},"162":{"model_id":"162","options":"36,37,39"}},"conf_list":"|AF1000|||AF1000A||36,37|||36,37,38|||36,37,38,39|||36,38|||36,38,39|||36,39|||36,37,39||||AF1000||36|AF1000A||36|AF1000|||AF1000||36|AF1000A"},"154":{"pid":"154","name":"MicroFlo™ Select Dispenser","configurable":"Yes","category":"Liquid Handling","models":[{"id":"234","model_name":"MFS"},{"id":"237","model_name":"MFS1536"}],"features":[{"id":"153","name":"Accommodates 6- to 384-well microplates, PCR trays, deep well microplates, microtubes and other tube configurations up to 4” in height","more":""},{"id":"154","name":"Dead volume < 1 mL","more":""},{"id":"155","name":"Automated dispense height adjustment","more":""},{"id":"156","name":"Easy maintenance with individually replaceable tips","more":""},{"id":"157","name":"Confidence-Plus lifetime warranty on cassette design","more":""},{"id":"158","name":"Bio-Stack compatible","more":""}],"upsells":[{"id":"53","name":"Liquid Handling Control Software","more":"","category":"Software","append":"LHCMFS"},{"id":"50","name":"Bio-Stack Microplate Stacker","more":"MicroFlo Select dispensers can be automated with the Bio-Stack for processing up to 30 standard height plates.","category":"Automation","append":""},{"id":"51","name":"Bio-Stack Twister II Microplate Handler","more":"MicroFlo Select dispensers can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates","category":"Automation","append":""}],"options":[{"id":"135","name":"Accommodates 6- to 1536-well microplates","more":"","category":"Hardware","append":""}],"include":{"135":[null]},"exclude":{"135":[null]},"configs":{"234":{"model_id":"234","options":""},"235":{"model_id":"235","options":"135"}},"conf_list":"|MFS||135|"},"148":{"pid":"148","name":"NanoQuot™ Microplate Dispenser","configurable":"Yes","category":"Liquid Handling","models":[{"id":"131","model_name":"NanoQuot"}],"features":[{"id":"17","name":"96-, 384- and 1536-well microplates","more":""},{"id":"18","name":"Wide volume range from 0.1 to 40 µl","more":""},{"id":"19","name":"Variable microplate heights","more":""},{"id":"21","name":"Organic solvent compatible including 100% DMSO","more":""},{"id":"22","name":"Uncomplicated onboard user interface","more":""},{"id":"23","name":"Includes NanoQuot PC Control software for complete control","more":""},{"id":"24","name":"Bio-Stack compatible","more":""},{"id":"25","name":"3rd party automation compatible","more":"NanoQuot dispensers can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details"}],"upsells":[{"id":"3","name":"Bio-Stack Microplate Stacker","more":"NanoQuot dispensers can be automated with the Bio-Stack for processing up to 30 standard height plates","category":"Automation","append":""},{"id":"4","name":"Bio-Stack Twister II Microplate Handler","more":"NanoQuot dispensers can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates.","category":"Automation","append":""}],"options":[],"include":[],"exclude":[],"configs":{"131":{"model_id":"131","options":""},"147":{"model_id":"147","options":"28"},"148":{"model_id":"148","options":"29"},"149":{"model_id":"149","options":"28,29"},"111":{"model_id":"111","options":""}},"conf_list":"|NanoQuot||28|||29|||28,29||||ELx405UCWS|||NanoQuot"},"131":{"pid":"131","name":"PowerWave™ Microplate Spectrophotometer","configurable":"Yes","category":"Detection","models":[{"id":"126","model_name":"MQX200R"},{"id":"16","model_name":"RPRWI"},{"id":"93","model_name":"RPRWI340/96"}],"features":[{"id":"104","name":"Absorbance detection","more":""},{"id":"63","name":"96 well plate reading","more":""},{"id":"64","name":"Monochromator wavelength selection from 340 nm to 999 nm","more":""},{"id":"65","name":"Shaking","more":""},{"id":"66","name":"Incubation to 50ºC","more":""},{"id":"67","name":"Gen5 pc software","more":""},{"id":"68","name":"Bio-Stack compatible","more":""},{"id":"69","name":"3rd party automation compatible","more":"PowerWave readers can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details"}],"upsells":[{"id":"12","name":"Gen5 Secure software","more":"Gen5 Secure provides features for compliance to 21 CFR Part 11","category":"Software","append":""},{"id":"41","name":"Bio-Stack Microplate Stacker","more":"Automate with the Bio-Stack Microplate Stacker for processing up to 30 standard height plates","category":"Automation","append":"BIOSTACK"},{"id":"42","name":"Bio-Stack Twister II Microplate Handler","more":"Automate with the Bio-Stack Twister II Microplate Handler for processing up to 320 standard height plates","category":"Automation","append":"BIOSTACKTII"}],"options":[{"id":"55","name":"96- and 384- well plate reading","more":"","category":"Hardware","append":""},{"id":"56","name":"6- to 384- well plate reading","more":"","category":"Hardware","append":""},{"id":"57","name":"Monochromator wavelength range from 200 nm to 900 nm","more":"","category":"Hardware","append":""}],"include":{"55":["57"],"56":["57"],"57":[null]},"exclude":{"55":["56"],"56":["55"],"57":[null]},"configs":{"16":{"model_id":"16","options":"55,57"},"91":{"model_id":"91","options":"55"},"92":{"model_id":"92","options":"57"},"93":{"model_id":"93","options":""},"126":{"model_id":"126","options":"56,57"}},"conf_list":"55,57,59|RPRWI||55,59|||57,59|||59|RPRWI340/96||56,57,59|MQX200R|||RPRWI340/96|||RPRWI340/96||56,57|MQX200R||56,57|MQX200R||55,57|RPRWI||55|||57||||RPRWI340/96||55,57|RPRWI||55|||57|||56,57|MQX200R||55,57|RPRWI||56,57|MQX200R|||RPRWI340/96"},"141":{"pid":"141","name":"Precision Power™ Software","configurable":"Yes","category":"Software","models":[{"id":"79","model_name":"PRCPWR UPGRADE V2"},{"id":"103","model_name":"PRCPWR V2"}],"features":[{"id":"112","name":"Windows 98, NT, 2000 and XP compatibility","more":""},{"id":"111","name":"Graphical User Interface (GUI)","more":""}],"upsells":[],"options":[{"id":"103","name":"Version 2 upgrade","more":"","category":"Other","append":""}],"include":{"103":[null]},"exclude":{"103":[null]},"configs":{"79":{"model_id":"79","options":"103"},"103":{"model_id":"103","options":""}},"conf_list":"103|PRCPWR UPGRADE V2|||PRCPWR V2"},"119":{"pid":"119","name":"Precision™ Microplate Pipetting System","configurable":"Yes","category":"Liquid Handling","models":[{"id":"45","model_name":"PRC384U"},{"id":"46","model_name":"PRC384/12"},{"id":"47","model_name":"PRC384M"},{"id":"48","model_name":"PRC384"}],"features":[{"id":"43","name":"Accommodates 96- and 384-well microplates or reservoirs compatible with 9 mm spacing between channels","more":""},{"id":"44","name":"Multi-channel pipette","more":""},{"id":"45","name":"User-configurable multi-station deck","more":""},{"id":"46","name":"Choice of BioTek or other pipette tips","more":""},{"id":"47","name":"Programmable onboard software","more":""},{"id":"48","name":"Bio-Stack compatible","more":""},{"id":"49","name":"3rd party automation compatible","more":"Precision pipetting systems can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details."}],"upsells":[{"id":"7","name":"Precision Power PC software","more":"Precision Power PC software is a graphical user interface offering users powerful and flexible program creation in a familiar Windows environment.","category":"Software","append":""},{"id":"8","name":"Bio-Stack Microplate Stacker","more":"Precision pipetting systems can be automated with the Bio-Stack for processing up to 60 standard height plates.","category":"Automation","append":""},{"id":"9","name":"Bio-Stack Twister II Microplate Handler","more":"Precision pipetting systems can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates.","category":"Automation","append":""}],"options":[{"id":"42","name":"8- and 12-channel pipettes","more":"","category":"Hardware","append":""},{"id":"43","name":"8-channel pipette","more":"","category":"Hardware","append":""},{"id":"44","name":"12-channel pipette","more":"","category":"Hardware","append":""},{"id":"45","name":"Multi-channel bulk dispenser","more":"","category":"Hardware","append":""}],"include":{"42":["45"],"43":[""],"44":["45"],"45":[null]},"exclude":{"42":["43,44"],"43":["42,44"],"44":["42,43"],"45":[null]},"configs":{"48":{"model_id":"48","options":"43"},"47":{"model_id":"47","options":"43,45"},"45":{"model_id":"45","options":"42,45"},"46":{"model_id":"46","options":"44,45"}},"conf_list":"43|PRC384||43,45|PRC384M||42,45|PRC384U||44,45|PRC384/12"},"144":{"pid":"144","name":"Precision™ XS Microplate Sample Processor","configurable":"Yes","category":"Liquid Handling","models":[{"id":"101","model_name":"PRC384/1M"},{"id":"102","model_name":"PRC384/1"}],"features":[{"id":"55","name":"Accommodates any test tube, microplate (up to 384 wells) or reservoir","more":""},{"id":"56","name":"Multiple liquid transfer tools","more":"Single-channel pipette, single-channel bulk dispenser and 8-channel pipette."},{"id":"57","name":"User-configurable multi-station deck","more":""},{"id":"58","name":"Liquid level sensing","more":""},{"id":"59","name":"Choice of BioTek or other pipette tips","more":""},{"id":"60","name":"Precision Power PC software","more":""},{"id":"61","name":"Bio-Stack compatible","more":""},{"id":"62","name":"3rd party automation compatible","more":"Precision XS pipetting systems can be integrated into many commercially available automated and robotic systems. Check with the automation manufacturer for confirmation and integration details."}],"upsells":[{"id":"10","name":"Bio-Stack Microplate Stacker","more":"Precision XS pipetting systems can be automated with the Bio-Stack for processing up to 60 standard height plates.","category":"Automation","append":""},{"id":"11","name":"Bio-Stack Twister II Microplate Handler","more":"Precision XS pipetting systems can be automated with the Bio-Stack Twister II for processing up to 320 standard height plates.","category":"Automation","append":""}],"options":[{"id":"52","name":"Multi-channel, autoclavable bulk dispenser, 8-channel dispense manifold","more":"","category":"Hardware","append":""}],"include":{"52":[null]},"exclude":{"52":[null]},"configs":{"102":{"model_id":"102","options":""},"101":{"model_id":"101","options":"52"}},"conf_list":"|PRC384/1||52|PRC384/1M"},"137":{"pid":"137","name":"Product Qualification Package","configurable":"Yes","category":"Accessories","models":[{"id":"60","model_name":"7340543"},{"id":"61","model_name":"7080532"},{"id":"62","model_name":"7260544"},{"id":"63","model_name":"7280520"},{"id":"64","model_name":"7100567"},{"id":"87","model_name":"4070530"},{"id":"88","model_name":"7330538"},{"id":"89","model_name":"7270514"},{"id":"90","model_name":"7140517"},{"id":"80","model_name":"7300514"},{"id":"83","model_name":"7090521"},{"id":"94","model_name":"7110524"},{"id":"97","model_name":"7310530"},{"id":"106","model_name":"7110558"},{"id":"213","model_name":"7130566"},{"id":"233","model_name":"7160528"},{"id":"240","model_name":"7150503"},{"id":"241","model_name":"7170521"}],"features":[{"id":"113","name":"Thorough procedures to allow a user to perform Installation, Operational and Performance Qualification","more":""},{"id":"114","name":"Periodic maintenance procedures","more":""}],"upsells":[{"id":"40","name":"Absorbance Test Plate","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":"7260522"}],"options":[{"id":"105","name":"µQuant Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"104","name":"MicroFill Qualification Package","more":"","category":"Other","append":""},{"id":"106","name":"Bio-Stack Qualification Package","more":"","category":"Other","append":""},{"id":"107","name":"Clarity Qualification Package (includes Luminescence Test Plate)","more":"","category":"Other","append":""},{"id":"108","name":"ELx405 Qualification Package","more":"","category":"Other","append":""},{"id":"109","name":"ELx50 Qualification Package","more":"","category":"Other","append":""},{"id":"110","name":"ELx800 Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"111","name":"ELx808 Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"112","name":"FLx800 Qualification Package","more":"","category":"Other","append":""},{"id":"113","name":"Gen5 Installation Qualification Package","more":"","category":"Other","append":""},{"id":"114","name":"PowerWave X Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"115","name":"PowerWave Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"116","name":"PowerWave XS Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"117","name":"Precision Qualification Package","more":"","category":"Other","append":""},{"id":"118","name":"Precision XS Qualification Package","more":"","category":"Other","append":""},{"id":"119","name":"Synergy HT Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"120","name":"Synergy 2 Qualification Package","more":"Note: The Absorbance Test Plate is required to run some of the procedures specified for the absorbance readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"134","name":"Synergy 4 Qualification Package","more":"Note: A Luminescence Test Plate is required to run some procedures specified on some luminescence readers, but it is not included and must be ordered separately.","category":"Other","append":""},{"id":"138","name":"NanoQuot Qualification Package","more":"","category":"Other","append":""},{"id":"139","name":"MicroFlo Select Qualification Package","more":"","category":"Other","append":""}],"include":{"105":[""],"104":[""],"106":[""],"107":[""],"108":[""],"109":[""],"110":[""],"111":[""],"112":[""],"113":[""],"114":[""],"115":[""],"116":[""],"117":[""],"118":[""],"119":[""],"120":[""],"134":[""],"138":[""],"139":[""]},"exclude":{"105":["104,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"104":["105,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"106":["105,104,107,108,109,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"107":["105,104,106,108,109,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"108":["105,104,106,107,109,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"109":["105,104,106,107,108,110,111,112,113,114,115,116,117,118,119,120,134,138,139"],"110":["105,104,106,107,108,109,111,112,113,114,115,116,117,118,119,120,134,138,139"],"111":["105,104,106,107,108,109,110,112,113,114,115,116,117,118,119,120,134,138,139"],"112":["105,104,106,107,108,109,110,111,113,114,115,116,117,118,119,120,134,138,139"],"113":["105,104,106,107,108,109,110,111,112,114,115,116,117,118,119,120,134,138,139"],"114":["105,104,106,107,108,109,110,111,112,113,115,116,117,118,119,120,134,138,139"],"115":["105,104,106,107,108,109,110,111,112,113,114,116,117,118,119,120,134,138,139"],"116":["105,104,106,107,108,109,110,111,112,113,114,115,117,118,119,120,134,138,139"],"117":["105,104,106,107,108,109,110,111,112,113,114,115,116,118,119,120,134,138,139"],"118":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,119,120,134,138,139"],"119":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,118,120,134,138,139"],"120":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,118,119,134,138,139"],"134":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,138,139"],"138":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,134,139"],"139":["105,104,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,134,138"]},"configs":{"64":{"model_id":"64","options":"108"},"60":{"model_id":"60","options":"111"},"87":{"model_id":"87","options":"109"},"63":{"model_id":"63","options":"115"},"62":{"model_id":"62","options":"114"},"61":{"model_id":"61","options":"112"},"88":{"model_id":"88","options":"110"},"89":{"model_id":"89","options":"105"},"90":{"model_id":"90","options":"104"},"136":{"model_id":"136","options":"113"},"80":{"model_id":"80","options":"116"},"83":{"model_id":"83","options":"119"},"94":{"model_id":"94","options":"117"},"97":{"model_id":"97","options":"106"},"106":{"model_id":"106","options":"118"},"107":{"model_id":"107","options":"107"},"213":{"model_id":"213","options":"120"},"233":{"model_id":"233","options":"134"},"240":{"model_id":"240","options":"138"},"241":{"model_id":"241","options":"139"}},"conf_list":"108|7100567||111|7340543||109|4070530||115|7280520||114|7260544||112|7080532||110|7330538||105|7270514||104|7140517||113|||116|7300514||119|7090521||117|7110524||106|7310530||118|7110558||107|||120|7130566||134|7160528||138|7150503||139|7170521"},"150":{"pid":"150","name":"Synergy™ 2 Multi-Mode Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"179","model_name":"SF"},{"id":"180","model_name":"SFA"},{"id":"181","model_name":"SFAD"},{"id":"182","model_name":"SFD"},{"id":"183","model_name":"SFP"},{"id":"184","model_name":"SFPA"},{"id":"137","model_name":"SLFPTA"},{"id":"138","model_name":"SLFPTAD"},{"id":"178","model_name":"SAD"},{"id":"177","model_name":"SA"},{"id":"185","model_name":"SFPAD"},{"id":"186","model_name":"SFPD"},{"id":"187","model_name":"SFPT"},{"id":"188","model_name":"SFPTA"},{"id":"189","model_name":"SFPTAD"},{"id":"190","model_name":"SFPTD"},{"id":"191","model_name":"SFT"},{"id":"192","model_name":"SFTA"},{"id":"193","model_name":"SFTAD"},{"id":"194","model_name":"SFTD"},{"id":"195","model_name":"SL"},{"id":"196","model_name":"SLA"},{"id":"197","model_name":"SLAD"},{"id":"198","model_name":"SLD"},{"id":"199","model_name":"SLF"},{"id":"200","model_name":"SLFA"},{"id":"201","model_name":"SLFAD"},{"id":"202","model_name":"SLFD"},{"id":"203","model_name":"SLFP"},{"id":"204","model_name":"SLFPA"},{"id":"205","model_name":"SLFPAD"},{"id":"206","model_name":"SLFPD"},{"id":"207","model_name":"SLFPT"},{"id":"208","model_name":"SLFPTD"},{"id":"209","model_name":"SLFT"},{"id":"210","model_name":"SLFTA"},{"id":"211","model_name":"SLFTAD"},{"id":"212","model_name":"SLFTD"}],"features":[{"id":"90","name":"Temperature control to 50ºC","more":""},{"id":"91","name":"Shaking","more":""},{"id":"92","name":"Gen5 Data Analysis software","more":""},{"id":"116","name":"6- to 1536-well microplates (luminescence up to 384)","more":""},{"id":"117","name":"3rd party automation compatible","more":""},{"id":"118","name":"Bio-Stack compatible","more":""}],"upsells":[{"id":"27","name":"Gen5 Secure","more":"For 21 CFR Part 11 compliance","category":"Software","append":"GEN5SECURE"},{"id":"45","name":"Bio-Stack Microplate Stacker","more":"Automate with the Bio-Stack Microplate Stacker for processing up to 30 standard height plates","category":"Automation","append":"BIOSTACK"},{"id":"46","name":"Bio-Stack Twister II Microplate Handler","more":"Automate with the Bio-Stack Twister II Microplate Handler for processing up to 320 standard height plates","category":"Automation","append":"BIOSTACKTII"}],"options":[{"id":"88","name":"Luminescence","more":"","category":"Detection Mode","append":"L"},{"id":"89","name":"Fluorescence Intensity Top / Bottom","more":"","category":"Detection Mode","append":"F"},{"id":"90","name":"Fluorescence Polarization","more":"","category":"Detection Mode","append":"P"},{"id":"91","name":"Time-Resolved Fluorescence","more":"","category":"Detection Mode","append":"T"},{"id":"92","name":"UV-Visible Absorbance","more":"","category":"Detection Mode","append":"A"},{"id":"87","name":"Dual Reagent Dispenser","more":"","category":"Hardware","append":"D"}],"include":{"88":[null],"89":[null],"90":["89"],"91":["89"],"92":[null],"87":[null]},"exclude":{"88":[null],"89":[null],"90":[""],"91":[""],"92":[null],"87":[null]},"configs":{"138":{"model_id":"138","options":"88,89,90,91,92,87"},"137":{"model_id":"137","options":"88,89,90,91,92"},"179":{"model_id":"179","options":"89"},"180":{"model_id":"180","options":"89,92"},"181":{"model_id":"181","options":"89,92,87"},"182":{"model_id":"182","options":"89,87"},"183":{"model_id":"183","options":"89,90"},"184":{"model_id":"184","options":"89,90,92"},"178":{"model_id":"178","options":"92,87"},"177":{"model_id":"177","options":"92"},"185":{"model_id":"185","options":"89,90,92,87"},"186":{"model_id":"186","options":"89,90,87"},"187":{"model_id":"187","options":"89,90,91"},"188":{"model_id":"188","options":"89,90,91,92"},"189":{"model_id":"189","options":"89,90,91,92,87"},"190":{"model_id":"190","options":"89,90,91,87"},"191":{"model_id":"191","options":"89,91"},"192":{"model_id":"192","options":"89,91,92"},"193":{"model_id":"193","options":"89,91,92,87"},"194":{"model_id":"194","options":"89,91,87"},"195":{"model_id":"195","options":"88"},"196":{"model_id":"196","options":"88,92"},"197":{"model_id":"197","options":"88,92,87"},"198":{"model_id":"198","options":"88,87"},"199":{"model_id":"199","options":"88,89"},"200":{"model_id":"200","options":"88,89,92"},"201":{"model_id":"201","options":"88,89,92,87"},"202":{"model_id":"202","options":"88,89,87"},"203":{"model_id":"203","options":"88,89,90"},"204":{"model_id":"204","options":"88,89,90,92"},"205":{"model_id":"205","options":"88,89,90,92,87"},"206":{"model_id":"206","options":"88,89,90,87"},"207":{"model_id":"207","options":"88,89,90,91"},"208":{"model_id":"208","options":"88,89,90,91,87"},"209":{"model_id":"209","options":"88,89,91"},"210":{"model_id":"210","options":"88,89,91,92"},"211":{"model_id":"211","options":"88,89,91,92,87"},"212":{"model_id":"212","options":"88,89,91,87"}},"conf_list":"88,89,90,91,92,87|SLFPTAD||88,89,90|SLFPTA||88|SLFPTA||89|SF||89,92|SFA||89,92,87|SFAD||89,87|SFD||89,90|SFP||89,90,92|SFPA||88,89,90,91,92|SLFPTA||88,89,90,91,92,87|SLFPTAD||92,87|SAD||92|SA||89,90,92,87|SFPAD||89,90,87|SFPD||89,90,91|SFPT||89,90,91,92|SFPTA||89,90,91,92,87|SFPTAD||89,90,91,87|SFPTD||89,91|SFT||89,91,92|SFTA||89,91,92,87|SFTAD||89,91,87|SFTD||88|SL||88,92|SLA||88,92,87|SLAD||88,87|SLD||88,89|SLF||88,89,92|SLFA||88,89,92,87|SLFAD||88,89,87|SLFD||88,89,90|SLFP||88,89,90,92|SLFPA||88,89,90,92,87|SLFPAD||88,89,90,87|SLFPD||88,89,90,91|SLFPT||88,89,90,91,87|SLFPTD||88,89,91|SLFT||88,89,91,92|SLFTA||88,89,91,92,87|SLFTAD||88,89,91,87|SLFTD||88,89,90,91,92,87|SLFPTAD||89,90,91,92,87|SLFPTAD||88,89,90,91,92,87|SLFPTAD"},"153":{"pid":"153","name":"Synergy™ 4 Multi-Mode Microplate Reader with Hybrid Technology™","configurable":"Yes","category":"Detection","models":[{"id":"217","model_name":"S4MLFPTA"},{"id":"218","model_name":"S4MLFPTAD"},{"id":"219","model_name":"S4MFT"},{"id":"220","model_name":"S4MFTD"},{"id":"221","model_name":"S4MFTA"},{"id":"222","model_name":"S4MFTAD"},{"id":"223","model_name":"S4MLFT"},{"id":"224","model_name":"S4MLFTD"},{"id":"225","model_name":"S4MLFTA"},{"id":"226","model_name":"S4MLFTAD"},{"id":"227","model_name":"S4MFPT"},{"id":"228","model_name":"S4MFPTD"},{"id":"229","model_name":"S4MLFPT"},{"id":"230","model_name":"S4MLFPTD"},{"id":"231","model_name":"S4MFPTA"},{"id":"232","model_name":"S4MFPTAD"}],"features":[{"id":"144","name":"Monochromator-based Fluorescence Intensity","more":""},{"id":"145","name":"Filter-based Fluorescence Intensity Top / Bottom","more":""},{"id":"146","name":"Time-Resolved Fluorescence","more":""},{"id":"147","name":"Temperature control to 50ºC","more":""},{"id":"148","name":"Shaking","more":""},{"id":"149","name":"6- to 1536-well microplates (luminescence up to 384)","more":""},{"id":"150","name":"Gen5 Data Analysis software","more":""},{"id":"151","name":"3rd party automation compatible","more":""},{"id":"152","name":"Bio-Stack compatible","more":""}],"upsells":[{"id":"47","name":"Gen5 Secure","more":"For 21 CFR Part 11 compliance","category":"Software","append":"GEN5SECURE"},{"id":"48","name":"Bio-Stack Microplate Stacker","more":"Automate with the Bio-Stack Microplate Stacker for processing up to 30 standard height plates","category":"Automation","append":"BIOSTACK"},{"id":"49","name":"Bio-Stack Twister II Microplate Handler","more":"Automate with the Bio-Stack Twister II Microplate Handler for processing up to 320 standard height plates","category":"Automation","append":"BIOSTACKTII"}],"options":[{"id":"133","name":"Luminescence","more":"","category":"Detection Mode","append":""},{"id":"129","name":"Fluorescence Polarization","more":"","category":"Detection Mode","append":""},{"id":"131","name":"UV-Visible Absorbance","more":"","category":"Detection Mode","append":""},{"id":"127","name":"Dual Reagent Dispenser","more":"","category":"Hardware","append":""}],"include":{"133":[null],"129":["128"],"131":["130,128"],"127":["130,128"]},"exclude":{"133":[null],"129":[""],"131":[""],"127":[""]},"configs":{"218":{"model_id":"218","options":"133,129,131,127"},"217":{"model_id":"217","options":"133,129,130,131,128"},"232":{"model_id":"232","options":"129,131,127"},"231":{"model_id":"231","options":"129,131"},"230":{"model_id":"230","options":"133,129,127"},"229":{"model_id":"229","options":"133,129"},"228":{"model_id":"228","options":"129,127"},"227":{"model_id":"227","options":"129"},"226":{"model_id":"226","options":"133,131,127"},"225":{"model_id":"225","options":"133,131"},"224":{"model_id":"224","options":"133,127"},"223":{"model_id":"223","options":"133"},"222":{"model_id":"222","options":"131,127"},"221":{"model_id":"221","options":"131"},"220":{"model_id":"220","options":"127"},"219":{"model_id":"219","options":""}},"conf_list":"126,129,130,131,128,127|S4MLFPTAD||126,129,130,131,128|S4MLFPTA||129,130,131,128|S4MLFPTA||129,130,131,128,127|S4MFPTAD||129,130,131,128|S4MFPTA||126,129,130,128,127|S4MLFPTD||126,129,130,128|S4MLFPT||129,130,128,127|S4MFPTD||129,130,128|S4MFPT||126,130,131,128,127|S4MLFTAD||126,130,131,128|S4MLFTA||126,130,128,127|S4MLFTD||126,130,128|S4MLFT||130,131,128,127|S4MFTAD||130,131,128|S4MFTA||130,128,127|S4MFTD||130,128|S4MFT||126,129,130,131,128,127|S4MLFPTAD||126,129,130,131,128|S4MLFPTA||126,129,130,131,128,132,127|S4MLFPTAD||126,129,130,131,128|S4MLFPTA||126,127|S4MLFPTAD||126|S4MLFPTA||126,129,130,131,128|S4MLFPTA||126,129,130,131,128,127|S4MLFPTAD||133,129,131|S4MLFPTA||133,129,130,131,128|S4MLFPTA||133,129,130,131,128,127|S4MLFPTAD||133,130,128|S4MLFT||133,129,131,127|S4MLFPTAD|||S4MFT||127|S4MFTD||131|S4MFTA||131,127|S4MFTAD||133|S4MLFT||133,127|S4MLFTD||133,131|S4MLFTA||133,131,127|S4MLFTAD||129|S4MFPT||129,127|S4MFPTD||133,129|S4MLFPT||133,129,127|S4MLFPTD||129,131|S4MFPTA||129,131,127|S4MFPTAD"},"133":{"pid":"133","name":"Synergy™ HT Multi-Mode Microplate Reader","configurable":"Yes","category":"Detection","models":[{"id":"13","model_name":"SIAFRT"},{"id":"84","model_name":"SIAFRTD"}],"features":[{"id":"93","name":"Luminescence","more":""},{"id":"94","name":"Fluorescence Intensity Top / Bottom","more":""},{"id":"95","name":"Time Resolved Fluorescence","more":""},{"id":"96","name":"UV-Visible Absorbance","more":""},{"id":"97","name":"Temperature control to 50ºC","more":""},{"id":"98","name":"Shaking","more":""},{"id":"99","name":"Gen5 Data Analysis Software","more":""},{"id":"119","name":"6- to 384-well microplates","more":""},{"id":"120","name":"3rd party automation compatible","more":""},{"id":"121","name":"Bio-Stack compatible","more":""}],"upsells":[{"id":"23","name":"Gen5 Secure software","more":"For 21 CFR Part 11 compliance","category":"Software","append":"GEN5SECURE"},{"id":"43","name":"Bio-Stack Microplate Stacker","more":"Automate with the Bio-Stack Microplate Stacker for processing up to 30 standard height plates","category":"Automation","append":"BIOSTACK"},{"id":"44","name":"Bio-Stack Twister II Microplate Handler","more":"Automate with the Bio-Stack Twister II Microplate Handler for processing up to 320 standard height plates","category":"Automation","append":"BIOSTACKTII"}],"options":[{"id":"93","name":"Dual Reagent Dispenser","more":"","category":"Hardware","append":"D"}],"include":{"93":[""]},"exclude":{"93":[""]},"configs":{"10":{"model_id":"10","options":""},"84":{"model_id":"84","options":"93"},"13":{"model_id":"13","options":""},"173":{"model_id":"173","options":""}},"conf_list":"|||93|SIAFRTD||93,94|SIAFRTD||102|SIAFRT|||||93,102|SIAFRTD||102,93|SIAFRTD|||SIAFRT||93|SIAFRTD||93|SIAFRTD"},"27":{"pid":"27","name":"Test Plate","configurable":"Yes","category":"Accessories","models":[{"id":"65","model_name":"7260522"},{"id":"214","model_name":"7770042"},{"id":"174","model_name":"7092092"}],"features":[],"upsells":[],"options":[{"id":"121","name":"Absorbance Test Plate","more":"For use with all BioTek automated absorbance readers. Tests linearity, accuracy, repeatability and alignment. Also tests wavelength accuracy of microplate spectrophotometers. NIST traceable.","category":"Other","append":""},{"id":"122","name":"Fluorescence Test Plate","more":"Works with all models of FLx800 and Synergy HT readers. Includes test plate in hard case, installation CD, install instructions, printed nominal values.","category":"Other","append":""},{"id":"123","name":"Gen5 Diagnostic Utility and Test Plate package","more":"Includes the Absorbance Test Plate (P/N 7260522) and the Gen5 Diagnostic Utility (P/N GEN5DIAG). Requires Gen5 software.","category":"Other","append":"7770042"}],"include":{"121":[""],"122":[""],"123":[""]},"exclude":{"121":["122,123"],"122":["121,123"],"123":["121,122"]},"configs":{"65":{"model_id":"65","options":"121"},"174":{"model_id":"174","options":"122"},"214":{"model_id":"214","options":"123"}},"conf_list":"121|7260522||122|7092092||121|7260522||122|7092092||123|7770042||121|7260522||123|7770042||122|7092092||121|7260522||123|7770042||122|7092092"},"60":{"pid":"60","name":"µQuant™ Microplate Spectrophotometer","configurable":"Yes","category":"Detection","models":[{"id":"21","model_name":"MQX200"}],"features":[{"id":"105","name":"Absorbance detection","more":""},{"id":"83","name":"6- through 384- well plate reading","more":""},{"id":"84","name":"Monochromator wavelength selection from 200nm to 999nm","more":""},{"id":"85","name":"On-Board software with pre-programmed and open assays","more":""}],"upsells":[{"id":"19","name":"Gen5 Software","more":"","category":"Software","append":"GEN5"},{"id":"20","name":"Gen5 Secure Software","more":"Gen5 Secure provides features for compliance to 21 CFR Part 11","category":"Software","append":"GEN5SECURE"},{"id":"21","name":"Gen5 ELISA","more":"","category":"Software","append":"GEN5ELISA"}],"options":[],"include":[],"exclude":[],"configs":{"21":{"model_id":"21","options":""}},"conf_list":"|MQX200||78|MQX200||78|MQX200|||MQX200|||MQX200"}};